Expansion tanks and the Minnesota Plumbing Code
Water expands as it is heated. In an open municipal system that pressure can often move back toward the main. In a closed system — for example after a backflow preventer, check valve, or pressure-reducing valve — it cannot. The temperature-and-pressure relief valve is a safety device, not a daily pressure regulator.
Why this comes up on water heater replacements
Many Twin Cities homes now have a backflow preventer, a pressure-reducing valve, or another device that keeps water from flowing backward into the public main. When a storage water heater then raises the temperature, the expanded volume has nowhere to go. Pressure in the house plumbing can rise. A listed thermal-expansion tank, installed on the cold-water side according to its listing and the manufacturer’s instructions, is a common way to absorb that volume. This page does not invent a tank size or a house-by-house requirement.
What Minnesota Rules part 4714.0608 actually says
The current Minnesota Plumbing Code is Minnesota Rules chapter 4714, which adopts the Uniform Plumbing Code with Minnesota amendments. Part 4714.0608, published electronically September 27, 2021, amends Uniform Plumbing Code section 608.5 on discharge piping from a temperature relief valve, a pressure relief valve, or a combination valve. The amendment requires that the discharge piping have no valves, obstructions, or means of isolation, and that it, among other things:
- be equal to the size of the valve outlet and discharge full size, pointing down, to the flood level of the area receiving the discharge;
- consist of materials rated for the operating temperature and approved for the use, or comply with ASME A112.4.1;
- discharge independently by gravity through an air gap to a safe place of disposal or within 18 inches of the floor, and not terminate in a crawl space;
- not be trapped or subject to freezing, not have a threaded terminal end, and not discharge into a water heater pan.
That is a rule about how the relief valve may discharge. It is not, by itself, a complete statement that every Minnesota water heater must have an expansion tank. This site did not find a separately numbered Minnesota amendment in chapter 4714 that restates a thermal-expansion-tank mandate in plain official language available to quote here. Ask a licensed plumber whether a listed expansion tank or other thermal-expansion control is required for your installation under the adopted code, especially if a backflow preventer, check valve, or pressure-reducing valve is present.
Do not cap the relief valve
The Department of Energy’s maintenance guidance treats the temperature-and-pressure relief valve as a critical safety device. If it drips, the cause may be the valve or it may be excess pressure. Capping the pipe, adding a shutoff, or routing the discharge in a way the rule forbids is unsafe. A licensed plumber can test the system and, if needed, install properly listed expansion control and a code-compliant discharge pipe. Related city permit notes are on the city index.
Need a licensed plumber for the work?
You can request a quote from a licensed Twin Cities plumber. A licensed local plumber will follow up. This site is an independent reference guide and may be compensated for referrals.
Common questions
Does Minnesota require an expansion tank on every water heater?
This page does not state a blanket yes or no beyond what the cited Minnesota rule actually says. Minnesota Rules, part 4714.0608, amends Uniform Plumbing Code section 608.5 on relief-valve discharge piping. Whether a listed expansion tank or other thermal-expansion control is required for a particular closed system is a question for a licensed plumber applying the Minnesota Plumbing Code and the manufacturer’s instructions.
Is a leaking relief valve always a bad valve?
Not always. A temperature-and-pressure relief valve that weeps can be a sign of high pressure, including thermal expansion in a closed system, or a sign that the valve itself has failed. Do not cap or valve off the discharge pipe. Call a licensed plumber.
Sources
- Minnesota Rules, part 4714.0608 (UPC 608.5 discharge piping amendment) — Minnesota Office of the Revisor of Statutes. Accessed November 20, 2026. Published electronically September 27, 2021. Amends Uniform Plumbing Code section 608.5 on temperature- and pressure-relief-valve discharge piping.
- Minnesota Rules 4714.0504, Water Heater Requirements — Minnesota Office of the Revisor of Statutes. Accessed November 19, 2026. Covers temperature, pressure, and vacuum relief devices. A shutoff valve shall not be placed between the relief valve and the water heater or on discharge pipes between the valves and the atmosphere.
- 2020 Minnesota Plumbing Code — Minnesota Department of Labor and Industry. Accessed November 19, 2026. Chapter 4714 took effect December 17, 2021. It incorporates the 2018 Uniform Plumbing Code with Minnesota amendments.
- Plumbing licenses, plan review, and permits — Minnesota Department of Labor and Industry. Accessed November 19, 2026.